The ideal on-line TOC Analyzer to achieve precise results even for your most challenging applications
Hach BioTector TOC analyzers are engineered to help operators address the toughest water quality challenges. Many plants struggle with high maintenance and downtime caused by sample contamination from salts, particulates, fats, oils, and greases. Conventional TOC analyzers often cannot keep up, leading to drifting results and costly interventions.
BioTector analyzers solve these problems with patented self-cleaning, two-stage advanced oxidation technology, designed to handle even challenging applications involving sludge, greases, salts, and particulates—without the need for filtration. Oversized tubing prevents blockages and lowers the risk of sample contamination. With minimal maintenance required and no calibration or operator intervention between service intervals, you can count on maximum uptime and reliable performance. Continuous monitoring and real-time control enable process optimization and help reduce overall operating costs.
Configurable to fit application needs, BioTector analyzers offer:
1. TIC & TOC (NPOC) System: Measures Total Inorganic Carbon (TIC) and Total Organic Carbon (TOC) content in liquid samples for accurate NPOC determination.
2. TC System: Measures Total Carbon (TC), representing the sum of TIC, NPOC, and VOC content.
3. VOC System: Measures TIC, TOC, TC, and VOC contents. The TOC result equals the combined NPOC and volatile organic carbon (POC) content.
BioTector’s robust design delivers precise results for a wide range of applications, from simple to demanding, and supports fast payback from savings in chemical dosing, waste management, and process efficiency.
For more details, to discuss your specific application, or to request other available versions, please contact us. Our team is ready to help you find the right solution for your plant.
| Ambient Temperature | 5 – 40 °C (41 – 104 °F) Air conditioning and heating options are available. |
| Communication | Modbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol) Except for Zone 1 certification then Modbus RTU, Modbus TCP/IP & Modbus TCP/IP Redundant is available |
| Cycle Time | From 6.5 minutes, depending on range and application |
| Data Storage | Previous 9999 analysis data on screen in the microcontroller memory and storage of data archive for the lifetime of the analyzer in the SD/MMC card. Previous 99 fault data on screen in the microcontroller memory and storage of fault data archive for the lifetime of the analyzer in the SD/MMC card. |
| Display | High-contrast 40-character x 16-line backlit LCD with CFL backlight |
| Drain Pressure | Typically ambient (for applications with high drain pressure, optional systems are available) |
| EExp / Hazardous Location | Certification options are available to European Standards, (ATEX Zone 1, Zone 2), North American Standards (Class I Division 2) and IECEx Zone 1 |
| Enclosure Rating | IP44; optional IP54 with air purge |
| Expected Measuring Range | Standard range < 5000 mg/L |
| Humidity | 5 – 85 % , non-condensing |
| Languages | English |
| Lower Limit of Detection (LOD) | 0.6 mg/L C |
| Measurement Method | Infrared measurement of CO2 after oxidation |
| Measurement Terms | Total Organic Carbon including: – Non Purgeable Organic Carbon (NPOC) and – Purgeable Organic Carbon (POC) B7000i’s TOC mode measures NPOC |
| Multi-Stream | 1, 2, 4 and 6 streams |
| Number of Channels | 1 |
| Number of streams | 1 |
| Outputs | 4 – 20 mA |
| Oxidation Method | Patented Two-Stage Advanced Oxidation Process using Hydroxyl Radicals. |
| Parameter | TOC, TIC, TC, VOC, after correlation COD, BOD |
| Particle Size | Up to 2 mm, soft particulates |
| Permissible Chloride Range | Up to 30% |
| Power Requirements (Hz) | 60 Hz |
| Power Requirements (Voltage) | 115 VAC |
| Power Supply | TOC/TIC (115VAC) |
| Range | 0 – 10000 mg/L C |
| Range Selection | Automatic or Manual Range Selection |
| Repeatability | ± 3 % of reading or ± 0.3 mg/L C, whichever is greater, with Automatic Range Selection |
| Response Time | TOC 6.5 minutes |
| Sample Inlet Temperature | 2 – 60 °C (36 – 140°F) |
| Sample Volume | Up to 8.0 mL |
| Service Interval | 6 months service intervals |
| User Interface | Microcontroller with membrane keyboard |
| Warranty | 12 months |
| Warranty | 1 |
| Weight | 90 – 120 kg Enclosure weight may change depending on system optional features. |
| What’s included? | Includes: B7000i analyzer, Tubing, Fuses, Ferrules, Drain, Acid & Base Dip Tubes, C02 Filter & B7000i User Manual |