Ensure uptime with accurate, low-level sodium measurements and predictive diagnostics.
Hach’s newest Sodium Analyzer, NA5600sc, monitors for low sodium levels with reliable online measurement technology and built-in automatic features like auto calibration and automatic electrode reactivation to save you process time. Whether you are monitoring for sodium in steam or boiler water, Hach’s Sodium instrument provides real-time, accurate readings in a smaller footprint for optimal use and maximum asset protection.
– Saves You Time: To maintain optimum response time and accuracy, the NA5600sc analyzer provides automatic electrode reactivation. Reactivation uses non-hazardous chemicals and eliminates the need for manual reactivation or electrode etching.
– Avoid Downtime: Predictive diagnostic tools, including Hach’s proprietary Prognosys technology, warning LEDs, and high visibility notification screens let you avoid unplanned downtime.
Please note that reagents are not included and need to be purchased separately.
| Accuracy | 0.01 – 2 ppb: ± 0.1 ppb 2 – 10,000 ppb: ± 5% |
| Acidity | < 50 ppm |
| Ambient Temperature | 5 – 50 °C (41 – 122 °F) |
| Analog Outputs | 6 isolated, 0 – 20 mA or 4 – 20 mA; load impedance: 600 Ohm maximum Connection: 0.644 – 1.29 mm² (24 – 16 AWG) wire; 0.644 – 0.812 mm² (24 – 20 AWG) recommended, twisted pair shielded wire |
| Calibration Method | Automatic with known addition Manual: 1 or 2 points |
| Dimensions | 681 mm x 452 mm x 254 mm (H x W x D) |
| Display | Colored 5.7” LCD |
| Electrode Type | Sodium ISE (ion specific electrode) electrode and reference electrode with KCl electrolyte |
| Fuse | Input power: T 1.6 A, 250 VAC Relays: T 5.0 A, 250 V |
| Include Autocalibration? | No |
| Include Cation Kit? | No |
| Inlet | Sample line and sample bypass drain: 6 mm O.D. push-to-connect fitting for plastic tubing Chemical and case drains: 7/16 inch I.D. slip-on fitting for soft plastic tubing |
| Interference Phosphate 10 ppm | < 0.1 ppb |
| Load of Analog Outputs | 600 |
| Lower Limit of Detection (LOD) | 0.01 ppb |
| Maintenance Interval | Every 90 days: refill electrolyte, reactivation, conditioning, and calibration solution |
| Material | Polyol case, PC door, PC hinges and latches, 304/316 SST hardware |
| Max. Concentration of Suspended Solids in Sample | < 2 NTU, no oil, no grease
For boiler sample type install approx. 100 µm filter |
| Mounting | Panel mount |
| Number of analog outputs | 6 |
| Number of Channels | 1 |
| Number of Relays | 6 |
| Options | Analyzer only |
| Parameter | Sodium |
| pH Range | 6 – 10 pH |
| Pollution Degree | 2 |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100 – 240 VAC |
| Protection Rating | IP65, PCBA housing |
| Range | 0.01 ppb – 10,000 ppb |
| Relative Humidity | 10 – 80%, non-condensing |
| Relay Output | 6; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum Connection: 1.0 – 1.29 mm² (18 – 16 AWG) wire; 1.0 mm² (18 AWG) stranded recommended, 5 – 8 mm O.D. cable |
| Repeatability | < 0.02 ppb or 1.5% reading (whichever is greater) within ±10 °C (±50 °F) variation |
| Response Time | From 0.1 ppb to 10 ppb: T90 ≤ 3 minutes, T95 ≤ 4 minutes From < 1 ppb to 100 ppb: T90 < 2 minutes, T95 < 3 minutes (about 150 s) |
| Sample conditioner | Di-isopropylamine (DIPA) (1 L/100 days) at 25 °C for a sample pH target of 10.5 |
| Sample Flow Rate | 100 – 150 mL/min (6 – 9 L/h) |
| Sample Pressure | 0.2 – 6 bar (3 – 87 psi) |
| Sample Temperature | 5 – 45 °C (41 – 113 °F) |
| Storage Conditions | -20 – 60 °C (2 -140 °F) |
| Warranty | 12 months |
| Weight | 14 kg (30.7 lb) with empty bottles |
| What’s included? | Hach NA5600sc Sodium Analyzer, 1 channel, with 1 channel installation kit and user manuals, reference electrode sodium, sodium ion selective electrode, empty DIPA bottle, the cover for DIPA bottle and the tray for DIPA bottle. Reagents have to be purchased separately. |