Experience Unmatched Efficiency and Reliability with the NH6000sc Ammonia Analyzer: High-Quality Measurements and Predictive Diagnostics for Optimal Performance
Discover the NH6000sc Ammonia Analyzer, an advanced online ammonia analyzer that combines transparent, high-quality measurement technology with exceptional reliability and a swift response time. Designed to handle a wide range of wastewater applications, this analyzer ensures precise and rapid results, including efficient sample preparation. The NH6000sc ammonia analyzer utilizes the gas sensing ammonium Electrode (GSE) measurement procedure, providing highly accurate and reliable ammonia readings. The NH6000sc is the new and improved replacement for the Amtax sc ammonia analyzer, offering enhanced performance and reliability for your ammonia analysis needs.
Environmentally controlled for rugged, outdoor installations, the NH6000sc ammonia analyzer is specifically designed for easy installation at the measurement point. Its gas sensing electrode is equipped with a self-cleaning membrane, minimizing maintenance requirements. The analyzer also features easy access to reagents and wear parts, making it incredibly user-friendly and efficient.
To ensure optimal performance and reliability, the NH6000sc ammonia analyzer must be connected to a digital Hach SC controller. These controllers provide seamless integration and enhanced operational efficiency, making your water analysis processes more streamlined and effective. Additionally, Prognosys, the predictive diagnostic system, allows you to be proactive in your maintenance by alerting you to upcoming instrument issues, giving you unwavering confidence in your measurements.
The sample needs to be prepared and filtered before analysis, filtration system is sold separately. Please note that reagents are not included and need to be ordered separately.
| Accuracy | With Standard Solution: Measuring range 1: ≤ 1 mg/L: 3% of the measured value + 0.02 mg/L > 1 mg/L: 5% of the measured value + 0.02 mg/L Measuring range 2: 3% of the measured value + 0.05 mg/L Measuring range 3: 3% of the measured value + 1.0 mg/L Measuring range 4: 4.5% of the measured value + 10 mg/L |
| Altitude | 2000 m (6562 ft.) maximum |
| Cable Length | Data cable length: < 50 m (164 ft) Power cable length: < 5 m (16.4 ft) |
| Certifications | CE, UKCA, CMIM, FCC, ISED, certified to UL and CSA safety standards by TÜV |
| Controller Compatibility | Digital SC Controller. Controllers are sold separately. |
| Dimensions | 575 x 991 x 425 mm (22.63 x 39.01 x 16.73 in.) |
| Enclosure Rating | Rating: IP55, NEMA UL50E 3R Material: PUR 66 |
| Filter Configuration | Use e.g. Filtrax |
| Indoor/Outdoor | Indoor or outdoor use |
| Lower Limit of Detection (LOD) | Measuring range 1: 0.02 mg/L NH₄-N Measuring range 2: 0.05 mg/L NH₄-N Measuring range 3: 1 mg/L NH₄-N Measuring range 4: 10 mg/L NH₄-N |
| Material | PUR 66 UV-resistant |
| Measurement Method | Gas sensing electrode (GSE) |
| Measuring Interval | 5, 10, 15, 20 or 30 min. (user adjustable) |
| Number of Channels | 1 |
| Operating Temperature Range | -20 – 45 °C (-4 – 113 °F); 95% relative humidity, non-condensing |
| Options | Flow detection |
| Outputs | Relay, analog outputs, network interface through SC Controller |
| Parameter | Ammonia |
| Permissible Chloride Range | ≤ 1000 mg/L Cl– |
| pH Range | 5 – 9 pH |
| Pollution Degree | 2 |
| Power Supply | Power supplied by the SC controller. With the SC4500, an additional power box is needed. Analyzer and heated drain tubing (powered by analyzer): 115 VAC or 230 VAC |
| Protection Class | Class 1 |
| Range | Measuring range 1: 0.02 – 5.0 mg/L NH₄-N Measuring range 2: 0.05 – 20 mg/L NH₄-N Measuring range 3: 1 – 100 mg/L NH₄-N Measuring range 4: 10 – 1000 mg/L NH₄-N |
| Repeatability | With Standard Solution: Measuring range 1: 3% of the measured value + 0.02 mg/L Measuring range 2: 2% of the measured value + 0.05 mg/L Measuring range 3: 2% of the measured value + 1.0 mg/L Measuring range 4: 2% of the measured value + 10 mg/L |
| Response Time T90 | Measuring range 1: ≤ 0.2 mg/L: 3 measurements required (15 total minutes minimum); > 0.2 mg/L: 1 measurement required (5 total minutes) Measuring range 2: < 5 minutes Measuring range 3: < 5 minutes Measuring range 4: < 5 minutes |
| Sample Flow Rate | 1.0 – 20.0 L/h to the analyzer from the external sample filtration |
| Sample Pressure | 2.5 bar (0.25 mPa) (36.3 psi) maximum |
| Sample Quality | Ultra filtrated or comparable (FX6x0 < 0.45 µm) |
| Sample Temperature | 4 – 40 °C (39 – 104 °F) |
| Special Remarks | The liquid level in the basin must be below the bottom of the analyzer |
| Storage Conditions | -20 – 60 °C (-4 – 140 °F); 95% relative humidity, non-condensing |
| Weight | Approximately 45 kg (99.21 lbs.) without chemicals |
| What’s included? | NH6000sc Ammonia Analyzer, Mounting Hardware, User Manual |