Maximum uptime and reliability for TOC analysis in drinking water applications
The Hach BioTector B3500dw, with patented, EPA drinking water method approved Two Stage, Advanced Oxidation Technology, provides accurate results you can be confident in, including the capacity to measure Total Inorganic Carbon (TIC) in addition to TOC. This capability helps users achieve a more complete understanding of water quality. The analyzer gives you maximum reliability and uptime for drinking water applications. The analyzer typically requires maintenance only twice a year for standard items like reagent replenishment, pump tube replacement and calibration, making it an affordable TOC analyzer option.
Because the analyzer body has one of the most compact analyzer footprints available, plants can free up critical wall space that can be used for other instruments. The B3500dw is designed for long maintenance intervals, typically requiring reagent replenishment only once every six months instead of bi-weekly or monthly. In addition to TOC, this analyzer includes the capacity to measure Total Inorganic Carbon (TIC), offering a more complete view of your water quality. It also has the ability to monitor two streams at the same time and calculate % TOC removal, eliminating the need for two separate analyzers. The result is accurate, low cost analyzis you can rely on.
With maximum reliability and uptime along with low operating costs, the B3500dw provides immediate, direct savings and is the industry’s choice when it comes to TOC analyzis for drinking water applications. In addition to TOC analyzis, the B3500dw can also be configured to measure Total Inorganic Carbon (TIC), supporting a more comprehensive water quality assessment.
For more details, to discuss specific application requirements, or to request additional BioTector versions, please contact us. Our team is ready to help identify the right solution for your plant.
| Ambient Temperature | 5 – 45 °C (41 – 113 °F) |
| Channels | 1 Channel / Grab sample-Calibration Port (includes two 4-20mA outputs enabled as standard) |
| Communication | Modbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol) |
| Cycle Time | From 5.5 minutes, depending on range and application |
| Data Storage | Previous 9999 reaction data Previous 99 fault events |
| Display | High contrast 40 character x 16 line backlit LCD with LED backlight |
| Humidity | 5 – 85 % (non-condensing) |
| Languages | English, Spanish, French, German Others available upon request. |
| Measurement Method | Infrared measurement of CO₂ after oxidation (DIN EN 1484:1997-08, ISO 8245:1999-03, EPA 415.1) |
| Multi-Stream | 1 stream |
| Number of streams | 1 |
| Oxidation Method | Patented Two-Stage Advanced Oxidation Process (TSAO) using Hydroxyl Radicals, Hach Company method 10261 (EPA approved for drinking water) |
| Parameter | TOC (NPOC), TIC, % TOC removal (with 2 streams) and COD, BOD after correlation |
| Particle Size | Up to 100 µm |
| Power Requirements (Hz) | 60 Hz |
| Power Requirements (Voltage) | 120 VAC |
| Range | 0 – 25 mg/L C |
| Range Selection | Automatic or manual range selection |
| Repeatability | ±3% of reading or ±0.03 mg/L, whichever is greater; Lower Limit of detection LOD = 0.06 mg/L |
| Sample Inlet Temperature | 0 – 60 °C (32 – 140 °F) |
| Service Interval | 6 month service intervals |
| User Interface | Microcontroller with membrane keyboard |
| Warranty | 12 months |
| Warranty | 1 |
| Weight | 46 kg (101.4 lb) |
| What’s included? | Includes: B3500dw analyser, Tubing, Fuses, Ferrules, Drain, Acid & Base Dip Tubes, C02 Filter & B3500dw User Manual |