Simple to Integrate. Simple to Operate.
An integral part of the most complete water analytics system for the Power industry. Hach provides a broad range of product options designed to work together into flexible solutions to meet your unique needs. The comprehensive approach saves you time on design, installation, training, maintenance, and operation.
| Analog Outputs | Five 0-20 mA or 4-20 mA analog outputs on analog output module |
| Cable Length | 10 m (33 ft) |
| Calibration Method | Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement |
| Communication | Modbus RS232/RS485, Profibus DPV1, Profinet optional |
| Communication | Analog: Five 0 – 20 mA or 4 – 20 mA analog outputs on each analog output module Up to two analog Input modules (0 – 20 mA or 4 – 20 mA). Each input module replaces a digital sensor input. Digital: |
| Communication Capabilities | mA Output |
| Conduit Openings | ½” NPT Conduit |
| Connection Drain Line | 8 mm tubing |
| Connections | ¼” NPT thread (6 mm or ¼” tubing advised) |
| Display | 3.5-inch TFT color display with capacitive touchpad |
| Electrical Certifications | CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, CMIM, Morocco |
| Enclosure Rating | UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4X Metal enclosure with a corrosion-resistant finish |
| Lower Limit of Detection (LOD) | < 1 ppb |
| Maintenance Interval | Membrane Lifetime: 6 months depending on sample |
| Material | Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl |
| Material Enclosures | Polycarbonate Aluminium (powder coated) Stainless Steel |
| Measuring Range | 0 to 2000 ppb (0-2 ppm) |
| Operating Temperature Range | -20 – 60 °C (-4 – 140 °F) (8 W (AC)/9 W (DC) sensor load) -20 – 45 °C (-4 – 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 – 60 °C (-1.33 W/°C) |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 100 – 240 VAC |
| Power Supply | Without power cord |
| Range | 0 – 2000 ppb (0 – 2 ppm) |
| Relay Functions | Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning |
| Relays | Two relays (SPDT);
Wire gauge: 0.75 – 1.5 mm² (18 – 16 AWG) AC controller DC controller |
| Repeatability | ±0.5 ppb or ±5%, whichever is greater |
| Reproducibility | ±0.5 ppb or ±2% whichever is greater |
| Response Time | For step change 1 – 40 ppb: < 30 s |
| Sample Flow Rate | 66 – 166 |
| Security Levels | 2 |
| Software available | Non-Cloud |
| Storage Conditions | -20 – 70 °C (-4 – 158 °F) |
| Temperature Compensation | Automatic in the range of 0 – 45 °C (32 – 113 °F) |
| Units | mg/L, ppm, µg/L, ppb, mbar, hPa, inch Hg, mmHg |
| Warranty | 12 months |
| Weight | 3.2 kg (7,2 lbs) |
| What’s included? | Controller, mounting hardware, oxygen sensor, temperature sensor, cable, flow-chamber, basic user manual |