Ultra low range turbidity measurement.
Filtertrak Laser Nephelometer offers the best resolution in the market. Detects changes in turbidity as low as 0.0005 NTU. Complies with USEPA approved Hach Method 10133 for regulatory reporting and compliance monitoring. Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers, sensor can be used with Hach’s new SC200 or SC1000 Digital Controllers. Includes Manual and Stablcal Turbidity Standards.
The FT660 is passing the torch to the TU5400 sc. The last day to order the FT660 is July 27, 2018. See the recommended products section of this page or visit HachTU5.com to learn more.
| Accuracy | (Defined according to ISO 15839) From ±3% of reading or ±5 mNTU, whichever is greater |
| Alarm | Three set-point alarms Two nephelometric set-point alarms (SOM required) |
| Cable Length | 1.8m (5.9 feet) |
| Calibration Method | Stablcal, stabilized formazin |
| Certifications | CE certified by Hach Company to EN61326 (industrial levels) |
| Certifications | Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1 |
| Communication | MODBUS® RS485/ RS232, PROFIBUS DP, HART available with sc controller |
| Controller | Single Digital |
| Dimensions (H x W x D) | 406 mm x 305 mm x 254 mm |
| Display Resolution | 0.001 mNTU up to 9.9999 mNTU |
| Fitting Type | Sample Inlet: 1/4-inch NPT female, 1/2-inch hose barb (provided); Drain: 1/2-inch NPT female, 1/2-inch hose barb (provided), clear drain tubing is recommended |
| Flow | 100 – 750 mL/min |
| Flow Rate | 100 – 750 mL / min (1.6 to 11.9 gal/hour) |
| Light Source | 660 nm Laser Diode |
| Lower Limit of Detection (LOD) | (Defined according to ISO 15839)
Less than 0.3 mNTU |
| Lowest Expected Reading | 5 mNTU using deionized, reverse osmosis water, based on statistical averages from three instruments |
| Measurement Frequency | One reading per second |
| Measuring Principle | Nephelometric light scatter at 90 degrees relative to incident monochromatic light beam |
| Mounting | Wall and floor stand |
| Number of Channels | 1 |
| Operating Humidity | 5 – 99 % non-condensing |
| Operating Temperature Range | 0 – 40 °C |
| Power Requirements (Voltage) | 24 VDC |
| Range | (0.0 – 5.0 NTU) 5000 mNTU = 5.000 NTU |
| Repeatability | + |
| Repeatability | (Defined according to ISO 15839) Better than ± 3.6 % of reading at 24 mNTU; as RSD (or as coefficient of variation) |
| Resolution | 0.01 mNTU from 10.00 – 99.99 mNTU |
| Resolution | 0.1 mNTU from 100.0 – 999.9 mNTU |
| Resolution | 1 mNTU from 1000 – 5000 mNTU |
| Sample Input | 0.25 ” NPT female thread (1/4″ compression
fitting provided) |
| Sample Output | 0.5 ” NPT female thread (1/2″ hose barb provided) clear drain tubing is recommended |
| Sample Temperature | 0 – 50°C (32 – 122°F) |
| Signal Average Time | User selectable from 0, 6, 30, 60, 90 seconds; default 90 seconds |
| Storage Conditions | -20 °C to 60 °C |
| Weight | 4.54 kg |
| What’s included? | Hach sc200 Controller, Mounting Hardware, sc200 Basic User Manual, FT660sc, FT660sc User Manual, and 1000 mL 800 mNTU Stablcal ®. (The controller power cord is ordered separately.) |