Sampling has never been this easy.
The AS950 All-Weather Refrigerated Sampler simplifies sampling with a large, full-color display for intuitive, single-screen programming, USB upload and download capabilities and the ability to copy programs sampler to sampler to save time on tedious programing, and an error alert and status screen to eliminate uncertainty and simplify troubleshooting. The custom-designed air-sensing thermostat controls temperature in accordance with USEPA and international guidelines, preserving samples regardless of outside temperatures and conditions.
| Alarm | Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage. |
| Automatic Shutdown | Multiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected) Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container. |
| Base Type | All Weather |
| Body material | IP24, low-density Polyethylene with UV inhibitor |
| Certifications | CE, UL |
| Communication Capabilities | USB and optional RS485 (Modbus) |
| Cooling system | Top mounted compressor and fan-forced air cooled condenser; 11/5 HP 115 VAC: 115 °C (239 °F) thermal overload protector, 7.1 locked rotor amps; 230 VAC: 120 °C (248 °F) thermal overload protector, 7.6 A peak start current; 3-sided wraparound plate type evaporator; Rigid foam insulation: 3 in. (7.6cm) sides, 5 in. (12.7cm) top, 6 in. (15.2cm) bottom; Lockable lid to prevent tampering with programming; Recovery Time: Sampler temperature recovers to 4°C within 5 minutes after door has been held open for one minute in 24°C (75°F) ambient environment while in an active cooling cycle; Pull Down Time: from 24°C (75°F) to 4°C (39°F), 20 minutes; Temperature Control: 4 (±0.8) °C (39 (±1.5) °F) |
| Diagnostics | View event and alarm logs as well as maintenance diagnostics |
| Dimensions | 76 x 81 x 130 cm (30 x 32 x 51 in.) |
| Dimensions (H x W x D) | 1300 mm x 760 mm x 810 mm |
| Display | 1/4 VGA, Color; self-prompting/menu-driven program |
| Factory Installed Options | TWO SENSOR PORTS Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors |RAIN/RS485 PORT Accepts Hach Rain Gauge (not included) or can be used as RS485 communications |NON-CONTACT LIQUID DETECT Sample volume accuracy for applications that require complete tubing replacement | Please contact your Hach sales representative for details. |
| Housing Material | PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller) |
| Inputs | One 0/4-20 mA input for flow pacing |
| Intake | Strainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications
Purge: Air purged automatically before and after each sample; Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt |
| Internal Clock | ±1 second per day at 25 °C (77 °F) |
| Lock Function | Access code protection prevents tampering |
| Manual Sampling | Initiates a sample collection independent of program in progress |
| Memory | Sample history: 4000 records; Data log: 325,000 records; Event log: 2000 records |
| Operating Mode | Continuous or non-continuous |
| Pollution Degree | 2 |
| Power Requirements (Hz) | 50 – 60 Hz |
| Power Requirements (Voltage) | 115 V |
| Probes included | No |
| Programs | Dual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers |
| Pump flow rate | 4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with 3/8-in intake tube typical |
| Rain Gauge Enabled | No |
| Refrigeration Components and Plumbing | Corrosion protected with conformal all exposed copper tubing is insulated to avoid sweating and condensation |
| Sample Container | 1 – 5.5 Gallon |
| Sample Interval | Select. in single increments from 1 to 9,999 flow pulses or 1 to 9,999 mins in one minute increments |
| Sample Pump | High-speed peristaltic, dual roller, with 0.95 ID x 0.16 OD cm (3/8 ID x 5/8-in. OD) pump tube; Pump body IP37, Polycarbonate cover |
| Sample Transport Velocity | 0.9 m/s with 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, 21 °C and 1524 m elevation |
| Sample Trigger | When equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded |
| Sample Volume Accuracy | Typical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation |
| Sample Volume Repeatability | Typical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation |
| Sampling Mode | Pacing: Time Weighted, Flow Weighted, Time Table, Flow Table, Event Distrib.: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle |
| Sensor Ports | 2 |
| Status Messages | Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature |
| Suction Hose Outer Diameter | 1/4″ and 3/8″ ID PTFE-lined Polyethylene with protective outer cover available in clear and black. |
| Tubing | Pump tubing: 9.5 mm ID x 15.9 mm OD Silicone
Intake tubing: 1.0 – 4.75 m minimum length, 1/4″ or 3/8″ ID Vinyl or 3/8″ ID PTFE-lined Polyethylene with protective outer cover (black or clear) |
| User Interface | Membrane switch keypad with 2 multiple function soft keys |
| User Interface Languages | Chinese, English, French, German, Italian, Spanish, Portuguese |
| Vertical Lift | 8.5 m using 8.8 m maximum of 3/8-in. vinyl intake tube at sea level at 20 to 25 °C |
| Warranty | 12 months |
| Weight | 86 kg |
| What’s included? | 1 ea. AS950 controller with sensor ports on 115V All Weather base 1 ea. Bottle kit (AW010060) includes 1- 5.5 gallon poly bottle w/cap (6494), composite tube support (8838) and full bottle shut-off (8847) 1 ea. 25′ vinyl intake tubing (920) 1 ea. strainer (926) |