Expertise + Simplicity
The Dual Parameter Chlorine and Turbidity panels offer CL17sc chlorine analyzer, TU5 Series TU5300sc Low Range Laser Turbidimeter and SC4500 controller in the convenience of one panel. These panel configurations are pre-engineered, ready to install, simple solutions that are designed to work together.
| Accuracy | ± 5% or ± 0.04 mg/L (whichever is greater) from 0 – 5 mg/L Cl₂ ± 10% from 5 – 10 mg/L Cl₂ |
| Air Purge | Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar (20 psig) maximum |
| Alerts | Low and high chlorine. Dirty cell. Low and high sample flow. |
| Certifications | SC4500 Controller is CE compliant and is TÜV listed to UL and CSA safety standards |
| Controller | SC4500 |
| Controller Compatibility | SC200, SC1000, SC4500. All controllers sold separately |
| Cycle Time | 2.5 minutes |
| Dimensions | 13″ x 28″ x 8.6 “(WxHxD) |
| Dimensions (H x W x D) | 711 mm x 330 mm x 218 mm |
| Drain | ½-inch ID flexible hose |
| Enclosure Rating | IP66 |
| Inlet | ¼-inch OD polyethylene tube, quick-disconnect fitting |
| Inlet Pressure | 0.3 – 5.2 bar (4.5 – 75 psig) supplied to Y-strainer 0.1 – 0.3 bar (1.5 – 5 psig) supplied to analyzer |
| Installation Kit | Pressure Regulator Installation Kit |
| Interferences | Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃. |
| Light Source | LED, measurement at 510 nm, 1 cm light pathlength |
| Lower Limit of Detection (LOD) | 0.03 mg/L |
| Mounting | Wall or rack |
| Operating Humidity | 0 – 90% relative humidity, non-condensing |
| Operating Temperature Range | 41 – 104 °F (5 – 40 °C) |
| Panel | Yes |
| Parameter | Chlorine, Turbidity |
| Power Requirements (Voltage) | 100 – 240 VAC ±10%, 50/60 Hz; 1 A |
| Process Connection | Sample Inlet ¼” OD tubing Sample Drain ¾” ID hose barb |
| Range | CL17sc 0 – 10 mg/L Cl₂ TU5300 0 – 700 NTU / FNU / TE/F / FTU |
| Range | 0 – 10 mg/L free or total residual chlorine |
| Reagent Consumption | 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days |
| Sample Flow Rate | 200 – 1000 mL/min |
| Sample Pressure | 4.5 – 75 psi (31 — 517 kPa) |
| Sample Requirements | Y-strainer filtration with 40-mesh screen or higher |
| Sample Temperature | 41 – 104 °F (5 – 40 °C) |
| Sensors | CL17sc TU5300sc |
| Solution Type | Drinking water, raw and treated |
| Weight | 49.5 lb (22.5 kg) |
| What’s included? | SC4500 Controller, Claros-enabled, 5x mA Output, 2 digital Sensors, 100-240 VAC, US plug (LXV525.99EA1551) Flow Sensor for TU5300sc and TU5400sc Laser Turbidimeter (LQV160.99.00002) CL17sc Colorimetric Chlorine Analyser with Pressure Regulator Installation Kit, without Reagents (8572400) User manual |

Tiếng Việt