Maximum uptime and reliability for TOC analysis in condensate applications
Through patented technology and semi-annual reagent replacement, the BioTector B3500c delivers 99.86% uptime with the lowest operating cost in condensate applications. The B3500c can also be configured to measure Total Inorganic Carbon (TIC), enabling flexible system setups for TIC & TOC (NPOC), TC, or VOC analyzis based on specific monitoring needs. This allows the analyzer to accurately assess inorganic and organic carbon content to match the requirements of your application.
Reliable and accurate TOC and TIC monitoring allows plants to make confident decisions that protect capital equipment and avoid downtime. The BioTector B3500c, through its innovative oxidation technology, provides maximum reliability and uptime without sacrificing accuracy. With the option to configure for TIC & TOC (NPOC), TC, or VOC analyzis, the B3500c supports monitoring of Total Inorganic Carbon in addition to Total Organic Carbon, giving users the flexibility to match testing approaches to their patented process needs. Industry-leading reliability combined with low total cost of ownership make the B3500c a natural choice for continuous TOC and TIC monitoring in condensate applications.
For more details, to discuss specific application requirements, or to request additional BioTector versions, please contact us. Our team is ready to help identify the right solution for your plant.
Direct measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon
Chemical Oxygen Demand, Biological Oxygen Demand via correlation
Volatile Organic Carbon via calculation
| Ambient Temperature | 5 – 45 °C (41 – 113 °F) |
| Communication | Modbus RTU, Modbus TCP/IP & Profibus (when the Profibus option is selected, the digital output signals are sent through the Profibus converter with its specific communication protocol) Except for Zone 1 certification then Modbus RTU, Modbus TCP/IP & Modbus TCP/IP Redundant is available |
| Cycle Time | From 5.5 minutes, depending on range and application |
| Data Storage | Previous 9999 reaction data |
| Display | High contrast 40 character x 16 line backlit LCD with LED backlight |
| EExp / Hazardous Location | Certification options are available to European Standards, (ATEX Zone 1, Zone 2), North American Standards (Class I Division 2) and IECEx Zone 1 |
| Humidity | 5 – 85 % (non-condensing) |
| Languages | English |
| Measurement Method | Infrared Measurement of CO₂ after Oxidation (DIN EN 1484:1997-08, ISO 8245:1999-03, EPA 415.1) |
| Multi-Stream | Up to 2 process streams and grab sample |
| Number of Channels | 1 Channel / Grab sample-Calibration Port (includes two 4-20mA outputs enabled as standard) |
| Number of streams | 1 |
| Oxidation Method | Patented Two-Stage Advanced Oxidation Process (TSAO) using Hydroxyl Radicals |
| Parameter | Direct measurement of Total Organic Carbon, Total Inorganic Carbon, Total Carbon Chemical Oxygen Demand, Biological Oxygen Demand via correlation Volatile Organic Carbon via calculation |
| Particle Size | Up to 100 µm |
| Permissible Chloride Range | Up to 30 % w/v |
| Power Requirements (Hz) | 60 Hz |
| Power Requirements (Voltage) | 115 VAC |
| Power Supply | TIC/TOC – 115V |
| Protection Class | IP44, standard fan cooled, maximum ambient temperature 45 °C IP54, air cooled, maximum ambient temperature 35 °C IP54, vortex cooled, maximum ambient temperature 50 °C |
| Range | 0 – 25 mg/L C |
| Range Selection | Automatic or Manual Range Selection |
| Repeatability | ± 3 % of reading or ± 0.03 mg/L, whichever is greater; Lower Limit of detection LOD = 0.06 mg/L |
| Sample Inlet Temperature | 0 – 60 °C |
| Service Interval | 6 month service intervals |
| User Interface | Microcontroller with membrane keyboard |
| Warranty | 12 months |
| Warranty | 1 |
| Weight | 46 kg |
| What’s included? | Includes: analyzer, tubing, fittings and manual |