| Alarm | Low Sample Flow Alarm (Flow < 2 L/min = Alarm)*** ***Potential Freed Contact (Contact Open = Alarm) |
| Ambient Temperature | 0 – 50 °C (32 – 122 °F); ≤ 95% relative humidity, non-condensing, non-corrosive |
| Analog Outputs | 4 – 20 mA** – temperature corrected pH (2.5 – 11 pH) 4 – 20 mA** – temperature corrected Conductivity (0 – 2,000,000 µS/cm) 4 – 20 mA** – turbidity (0 – 400 FNU) **Active / maximum load: 500 Ω / galvanically isolated |
| Dimensions | W x H x D: 800 × 1000 x 300 mm (31.5” × 39.4” × 11.8”) |Overall dimensions, including flanges, shock absorbers and lifting bolds; W x H x D: 810 x 1135 x 310 mm (31.9” × 44.7” × 12.2”) |
| Earth Connection | Dry and clean grounding pole with low impedance (< 1 Ω) with an earth cable of > 2.5 mm² (13 AWG) |
| Housing Material | Fiberglass-reinforced unsaturated polyester], with door, including viewing window Ingress protection IP56 (corresponds to NEMA 4) |
| Installation Category | Maritime – [Machinery spaces, control rooms, accommodation, bridge] DNV GL-CG-0339 Class A, except Class B for damp heat exposed by vibrations from surroundings max. 1 mm/speak conform Class A |
| Instrument | SC1000, pHD sc, Inductive Conductivity |
| Model | SM100 |
| Parameter | pH; Conductivity |
| Power | 100-240 VAC ±10%, 50/60 Hz, 460 VA |
| Range | pH: 0 – 14 Cond.: 200 µS/cm – 2000 mS/cm |
| Sample Requirements | Seawater/Polluted seawater/Fresh water with NaOH/Residue particles of HFO combustion / Salts (Na₂SO₄ etc.) Pressure: 0 – 6 bar (0 – 87 PSI) Temperature: 0 – 50 °C (32 – 122 °F) Density: 1020 kg/m³ |
| Storage Conditions | 0 – 50 °C (32 – 122 °F); ≤ 95% relative humidity, non-condensing, non-corrosive |
| Weight | ± 55 kg (176 lb) |
| What’s included? | ScrubberMonitor Cabinet with LXV400.99.00121 SC1000 Controller Probe Module LXV402.99.00201 SC1000 Controller Display Module DPD1P1.99M pHD sc pH Sensor D3725E2T.99M 3700-Series Inductive Conductivity Sensor |