Expertise + Simplicity
The Single Parameter Turbidity Panel offers the TU5300sc Low Range Laser Turbidimeter and the SC4500 Controller in one convenient package. These pre-engineered, ready-to-install panels are designed to work seamlessly together, providing a simple and effective solution for your turbidity measurement needs.
Specifications:
TU5300sc Low Range Laser Turbidimeter. Ensures precise and reliable turbidity measurements. Model LXV445.53.B311
SC4500 Controller: Claros-enabled with 5x mA output and 2 digital sensor channels, supporting versatile connectivity. Model LXV525.99EA1551
Flow Sensor: Ensures optimal performance of the turbidity measurement system. Included for optimal performance. Model LQV160.99.00002
Choose Hach’s Single Parameter Turbidity Panels for an easy-to-use, integrated solution that simplifies your turbidity measurement process.
| Cable Length | 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories |
| Calibration Method | For Formazin and Stablcal: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) Australian ACMA Marking |
| Controller | SC4500 |
| Dimensions (H x W x D) | 685.8 mm x 584.2 mm x 292.1 mm |
| Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Material | ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS |
| Mounting | Wall or rack mounting |
| Mounting Configurations | Wall Mount |
| Operating Humidity | Relative humidity: 5 – 95% at different temperatures, non-condensing |
| Power Requirements (Voltage) | 100 – 240 VAC ±10%, 50/60 Hz; 1 A |
| Process connection | Sample drain: 1/4″ OD tube or hose barb |
| Range | Sensor Monitoring Option: TU5300sc 0 – 700 NTU/FNU/TE/F/ FTU |
| Sample Flow Rate | 100 – 1000 mL/min, optimal flow rate: 200 – 500 mL/min |
| Sample Inlet Connection | ¼” OD tubing |
| Sample Pressure | 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 – 40 °C (35.6 – 104°F) |
| Sample Temperature | 2 – 60°C (35 – 140°F) |
| Sensor to Controller Distance (Maximal) | 1000 m (3280 ft), per RS485 |
| Sensor Type | Digital output |
| Solution Type | Drinking water, raw and treated |
| Storage Conditions | -40 to 60 °C (-40 to 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC |
| Verification | Liquid: Stablcal®, Formazin (0.1 to 40 NTU) Dry: Glass Rod at <0.1 NTU |
| Weight | 13.8 kg / 30.5 lbs |
| What’s included? | TU5300sc Low Range Laser Turbidimeter (LXV445.53.B3112), SC4500 Controller, Claros-enabled, 5x mA Output, 2 digital Sensors, 100-240 VAC, US plug (LXV525.99EA1551) Flow Sensor for TU5300sc and TU5400sc Laser Turbidimeter (LQV160.99.00002) |