The next standard in the evolution of turbidity
Compliant with EPA approved Hach Method 10258 and perfect for membrane filtration applications, the TU5400sc employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series® turbidimeter.
The TU5400sc Ultra-High Precision Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. With a 10mL sample size, response time is over 15 times faster than an FT660. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. With a mounting pattern identical to the FT660, replacing your previous turbidimeter is fast and simple.
All of this, along with the ability to measure to 0.0002 NTU, gives you the next standard in the evolution of turbidity.
A flow meter is included with this turbidimeter that continuously measures flow through the instrument and displays the flow value on screen. Current flow can be output to SCADA via 4-20mA or digital communications.
Ensure that your turbidimeter is always functioning properly with this TU5’s System Check capability. With the ability to provide information on measurement status and vial cleanliness, you can have full confidence in your turbidity measurement.
RFID technology included with this turbidimeter delivers easy calibration and simple, paperless turbidity measurement comparisons between your process turbidimeter and the TU5200.
| Accuracy | ±2% or 0.01 NTU from 0 – 40 NTU ±10% of reading from 40 – 1000 NTU based on Formazin primary standard |
| Cable Length | 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories |
| Calibration Method | For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking |
| Communication | System Check & RFID |
| Controller | 2 Channels, 100-240 VAC |
| Dimensions (H x W x D) | 249 mm x 268 mm x 190 mm |
| Enclosure Rating | Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument |
| Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
| Instrument | With Flow Sensor |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Material | ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS |
| Model | TU5400sc |
| Mounting Configurations | Wall Mount |
| Operating Humidity | Relative humidity: 5 – 95% at different temperatures, non-condensing |
| Operating Temperature Range | 0 – 50 °C (32 – 122 °F) |
| Options | Process Head & Flow Sensor |
| Range | EPA: 0 – 700 NTU / FNU / TE/F / FTU 0 – 100 mg/L 0 – 175 EBC ISO: |
| Regulatory | EPA |
| Repeatability | Better than 1% of reading or ±0.002 NTU (TU5300sc) or ±0.0006 NTU (TU5400sc) on Formazin at 25 °C (77 °F), whichever is greater |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC |
| Response Time | TU5300sc: T90 <45 seconds at 100 mL/min TU5400sc: T90 <30 seconds at 100 mL/min |
| Sample Flow Rate | 100 – 1000 mL/min; optimal flow rate: 200 – 500 mL/min |
| Sample Pressure | 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 – 40 °C (35.6 – 104 °F) |
| Sample Temperature | 2 – 60 °C (35 – 140 °F) |
| Signal Average Time | TU5300sc: 30 – 90 seconds TU5400sc: 1 – 90 seconds |
| Storage Conditions | -40 – 60 °C (-40 – 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC |
| Verification | Liquid: Stablcal®, Formazin (0.1 – 40 NTU) Dry: Glass Rod at <0.1 NTU |
| Weight | 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories |
| What’s included? | Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware |

Tiếng Việt